Proteomics for Pre-Clinical Studies

Principle of bottom-up proteomics

Multi-omics analysis is becoming increasingly prevalent in both academic and industrial research, with proteomics playing a pivotal role as proteins serve as the direct and critical link between genotype and phenotype. Mass spectrometry (MS)-based proteomics employs mass spectrometers to profile and quantify the proteome of various biological samples. Depending on the sample preparation strategy, MS-based proteomics is classified into "top-down" and "bottom-up" approaches. Top-down proteomics profiles intact proteins, whereas bottom-up proteomics involves digesting the proteome into peptides before analysis.

Compared to intact proteins, peptides are easier to ionize and separate using reverse-phase liquid chromatography, significantly increasing throughput and enabling the analysis of complex proteomes. As a result, bottom-up proteomics is the most widely used MS-based proteomics method today. Unless otherwise specified, the term "proteomics" in this article refers specifically to bottom-up proteomics.

A diagram of a scientific experiment

Description automatically generatedThe typical workflow of bottom-up proteomics analysis is shown in Figure 1. After sample collection, the proteome is extracted and digested with a protease, typically trypsin. The resulting peptides are analyzed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Reverse-phase liquid chromatography separates the peptide mixture over time, ensuring that the peptides entering the mass spectrometer at any given moment are relatively simple in composition. Once all peptide components are analyzed, the generated mass spectra are compared against a spectral library to identify peptide amino acid sequences. Peptide signal intensities are then used for quantification. This process, known as library searching, provides researchers with interpretable quantitative data for downstream bioinformatics analysis.

 

Two data acquisition methods.

A diagram of data acquisition method

Description automatically generatedMass spectrometry analysis in proteomics relies on two key stages: MS1 and MS2. MS1, or the precursor scan, measures the mass-to-charge ratio (m/z) and intensity of ions in a sample, providing an overview of the peptide population and enabling initial quantification. MS2, or the fragmentation scan, focuses on breaking selected precursor ions into smaller fragments, allowing the identification of peptides based on their unique fragmentation patterns.

 

The roles of MS1 and MS2 differ depending on the data acquisition method (Figure 2). For instance, in data-dependent acquisition (DDA), MS1 selects a limited number of precursor ions (e.g., the top 20 most intense) for subsequent MS2 analysis, which may result in the loss of lower-abundance peptide information. In contrast, data-independent acquisition (DIA) systematically fragments all ions within defined mass windows, leveraging both MS1 and MS2 data for comprehensive peptide quantification and identification. DIA's ability to use MS2 intensities extensively for quantification enhances its precision and has made it the preferred approach in modern proteomics.

 

Label-free proteomics

Proteomics can be classified into label-based and label-free approaches depending on whether isotopic labeling is applied to proteins (or peptides) during sample preparation. For untargeted proteomics, label-based methods such as Tandem Mass Tags (TMT) proteomics use multiplex labeling techniques to label, mix, and analyze samples in a single MS run, which minimizes systematic errors introduced by multiple runs and offers high precision for quantitative comparisons between samples. However, due to its underlying principles, label-based approaches often suffer from limitations such as restricted sample numbers, lower detection depth (fewer proteins identified), and higher costs associated with labeling reagents.

In contrast, label-free proteomics can fully leverage the strengths of DIA technology to achieve greater detection depth and flexibility in sample throughput, enabling cost-effective analysis of large sample cohorts. Since label-free methods analyze each sample individually in MS runs without labeling, systematic errors between samples may arise. Therefore, robust experimental monitoring and reliable data normalization processes are indispensable for accurate label-free quantification.

A graph of different colored bars

Description automatically generated with medium confidenceIn label-free proteomics, the choice of liquid chromatography (LC) elution gradient time significantly influences the number of proteins detected in a sample. Longer elution time allows more thorough peptide separation, enhancing the MS detection efficiency especially for low-abundance peptides. The selection of the elution time gradient depends on the experimental goals, sample type, and efficiency requirements. For instance, protein identification numbers under different LC gradient times for 4D-DIA can be referred to in Figure 3. By comparison, the latest Astral MS platform can significantly reduce the required elution time (Figure 4).

Quantification of label-free proteomics (考虑加图,或者表格,考虑缩减)

Mass spectrometry quantifies peptides primarily by detecting the chromatographic peak areas of peptide ions in MS1 scans. In label-based proteomics, such as TMT (Tandem Mass Tag), chemical tags are incorporated into peptides, generating reporter ions during MS2 fragmentation. These reporter ions allow for relative quantification by measuring their respective intensities.

In contrast, label-free proteomics does not rely on reporter ions; instead, all detected peptide ion intensities in MS1 can potentially be used for relative protein quantification. Since label-free approaches analyze each sample in a separate mass spectrometry run, this introduces variability in peptide identification across samples. Therefore, robust data normalization strategies are essential to minimize technical variation and ensure accurate quantification.

It is important to note that label-free proteomics, as well as all untargeted proteomics methods based on mass spectrometry, currently provide only relative quantification rather than absolute quantification. This means that protein quantification can only be used to compare the relative abundance of the same protein across different samples, but not to compare the abundance of different proteins within the same sample, nor to provide precise protein concentration measurements.

To address this limitation, several quantification strategies have been developed. iBAQ (Intensity-Based Absolute Quantification) estimates protein abundance by summing the signal intensities of theoretically observable peptides from a given protein. However, due to inherent differences in peptide ionization efficiency, iBAQ cannot ensure precise comparisons between different proteins. Moreover, iBAQ is sensitive to experimental conditions and batch effects, making it less reliable for large-scale analyses.

To improve cross-sample comparability, riBAQ (relative iBAQ) introduces additional normalization based on total protein intensity within each sample, allowing iBAQ values to be more comparable across different datasets. However, riBAQ still has limitations, including reduced quantification accuracy for low-abundance proteins and the potential introduction of additional variability during normalization. Furthermore, as riBAQ is derived from iBAQ, it inherits iBAQ’s fundamental limitations regarding ionization efficiency differences.

In contrast, MaxLFQ (Maximal Peptide Ratio Extraction for Label-Free Quantification) constructs a peptide intensity ratio network to achieve more robust relative quantification without relying on theoretical peptide numbers. It excels at minimizing technical noise and reducing batch effects, making it particularly well-suited for large-scale proteomics studies. As a result, MaxLFQ remains the preferred method for high-precision protein quantification, while iBAQ and riBAQ are more appropriate for estimating protein abundance under specific conditions.

 

Proteomics and transcriptomic (图)

Proteomics and transcriptomics provide insights into biological systems from different dimensions, and their data are not always fully positively correlated. This discrepancy arises from factors such as differences in degradation rates or the detection limits of proteomics. For instance, Nectin4, a crucial tumor biomarker and drug target, shows almost no correlation between its protein and mRNA expression levels. On the other hand, histone proteins, characterized by long degradation cycles, exhibit high protein expression despite low detected mRNA levels. These examples highlight the unique contributions and limitations of each omics approach, emphasizing the necessity of integrating proteomic and transcriptomic data to gain a comprehensive understanding of molecular mechanisms.

Thus, in practice, proteomics and transcriptomics are often used in combination to achieve optimal research outcomes. On one hand, proteomics provides direct quantification of proteins and, when integrated with transcriptomic data, facilitates the study of regulatory mechanisms across transcriptional and translational levels. On the other hand, the high throughput and broad coverage of transcriptomics compensate for the limitations of proteomics in quantifying low-abundance proteins. Furthermore, due to the nature of mass spectrometry-based relative quantification, proteomics can typically only compare the relative expression of the same protein across different samples, making it challenging to assess the absolute expression levels of different proteins. In contrast, appropriately normalized mRNA quantification allows precise comparisons of expression levels between different genes. By integrating protein quantification with mRNA quantification through correlation analysis, transcriptomic data serve as a valuable reference for estimating protein expression levels.

Proteomics Database of Tumor Model

The selection of tumor models plays a crucial role in cancer mechanism research and anticancer drug development. A large-scale, high-quality tumor model proteomics database enables researchers to flexibly compare the relative expression levels of biomarkers and potential targets across different models, facilitating the selection of the most appropriate biological models for their studies.

 

Compared to traditional immunohistochemistry (IHC)-based model selection strategies, proteomics databases provide a valuable complement by significantly reducing the number of required IHC experiments. This not only lowers experimental costs but also shortens the time needed for model screening, enhancing research efficiency.

 

Currently, our PDX model database, HuBase, contains high-quality label-free proteomics data from over 400 PDX models, all acquired using Data-Independent Acquisition (DIA) technology. The database continues to expand, and in the future, we plan to further incorporate organoid models and cell line models to establish a more comprehensive tumor model proteomics database, supporting cancer research and precision medicine.

Addressing Murine Protein Interference in PDX Model Proteomics

In patient-derived xenograft (PDX) model proteomics, human tumor tissues are implanted into mouse hosts, where murine stromal cells inevitably infiltrate the samples. This contamination compromises the accurate identification and quantification of human proteins, particularly given the high sequence homology between human and mouse proteins. Without removing murine proteins, quantification biases and misidentifications may occur, leading to incorrect biological interpretations.

Compared to transcriptomics, proteomics faces a greater challenge from murine protein interference. At the transcriptomic level, mRNA exhibits higher species specificity, and high-throughput sequencing offers extensive coverage, minimizing the impact of murine cells on human transcript quantification. However, in proteomic studies, several factors make murine protein interference significant:

  1. Sequence homology: The amino acid sequence similarity between human and mouse proteins is much higher than that of mRNA, making them difficult to distinguish in mass spectrometry.
  2. Limitations of mass spectrometry-based identification: Bottom-up proteomics relies on peptide-level identification rather than full protein sequences, exacerbating the issue of distinguishing homologous proteins.
  3. Complexity of mixed samples: The proportion of murine stromal cells and human tumor cells varies significantly across PDX samples. If murine proteins are not removed, data bias may occur, leading to misleading quantification of human proteins.

Our studies indicate that if murine proteins are not removed, 30-40% of differentially expressed proteins may be affected, potentially distorting biological interpretations of tumor-related pathways. Therefore, in PDX model proteomics, we recommend and employ the "separate-then-run" strategy, where murine cells are depleted before mass spectrometry analysis, ensuring precise quantification of human proteins.

All proteomics data in our PDX model proteomics database are processed strictly following the "separate-then-run" strategy to deliver high-quality, reliable proteomic data, advancing cancer research and precision medicine.

 

Batch Effect Adjustment

In large-scale tumor model proteomics studies, data collection often spans multiple experimental batches due to variations in tumor model culture cycles and other experimental factors. However, batch-to-batch variability—driven by differences in time points, experimental conditions, and instrument states—can introduce batch effects that obscure or even mask true biological differences. Therefore, in addition to strictly adhering to standardized protocols and maintaining consistent experimental conditions, batch effect correction is crucial for ensuring data reliability and comparability.

Given that log-transformed proteomics data approximately follow a normal distribution, ComBat is widely used for batch effect correction in proteomics datasets. ComBat is a statistical approach designed to correct batch effects in high-throughput biological data, such as proteomics and gene expression datasets. Using an empirical Bayes framework, ComBat effectively removes systematic biases while preserving true biological variation. Unlike simple normalization methods, ComBat models both batch-specific mean shifts and variance differences, making it particularly effective at mitigating unwanted technical variation. It is especially useful when batch effects are known and need to be removed without distorting underlying biological signals.

To assess the reliability of ComBat correction, we employed multiple evaluation strategies:

  1. We tested the protein expression reproducibility of models measured across different batches. Before ComBat correction, the correlation coefficient (R²) of repeated measurements was only 0.7, indicating substantial batch effects. After ComBat correction, R² increased significantly to 0.92, demonstrating improved data consistency (Figure).

  1. The Dimensionality Reduction Analysis also indicates the effectiveness of ComBat Batch Effect Removal. Before ComBat correction, the UMAP dimensionality reduction analyses showed that batch effects were the dominant source of variation across samples (Figure). While after ComBat correction, samples from different batches no longer clustered separately, and tumor samples of the same type grouped more closely together, indicating that biological differences became the primary source of variation in the dataset.

  1. The correlation ship also significantly increases after the ComBat batch effect correction. Before ComBat correction, the correlation between protein expression and mRNA expression was relatively low, likely due to batch effects. While after ComBat correction, the correlation coefficient significantly improved, approaching the levels observed in single-batch datasets, further validating the effectiveness of the correction.

In summary, ComBat correction effectively eliminates batch effects, enhances data consistency, reduces technical variation, and strengthens the biological interpretability of proteomics data. In our PDX proteomics studies, we systematically apply ComBat correction to ensure high-quality, reliable, and biologically meaningful data for downstream analyses. (图)

Estimating Protein Expression Levels: How to Determine High or Low Expression in the Database?

One of the most common questions users encounter when using tumor model proteomics databases is: How can we determine whether a protein is highly or lowly expressed? However, this is not a straightforward question to answer.

As mentioned earlier, label-free proteomics provides relative quantification, meaning that the expression levels of the same protein can be compared across different samples, but the quantitative values of different proteins are not inherently comparable. Therefore, when selecting tumor models, we generally recommend ranking a specific protein across different models rather than directly interpreting its absolute expression level. If precise expression levels are required, we suggest validating the results with immunohistochemistry (IHC) experiments.

How to Estimate Protein Expression Levels in the Database?

Although, in theory, the quantitative values of different proteins cannot be directly compared, we aim to leverage available data to provide useful reference points to help users roughly estimate protein expression levels in the database. In practice, we have observed a strong correlation between a protein’s quantitative value and its actual expression level. For example, housekeeping genes such as GAPDH, PGK1, and PPIA, which are known to be highly expressed, typically have quantitative values exceeding those of 90% of other proteins.

Based on this observation, we have incorporated several visualization tools into the HuBase database to assist users in evaluating protein expression levels:

 

By integrating proteomics and transcriptomics data, these tools allow users to gain a more comprehensive understanding of the expression levels of target proteins.

Phosphoproteomics

Phosphopeptide Enrichment

Protein phosphorylation is a crucial post-translational modification (PTM) that typically occurs on serine, threonine, or tyrosine residues. It plays a key role in regulating protein activity and interactions with other molecules and is a fundamental mechanism in cellular signaling pathways. The study of phosphorylation modifications is known as phosphoproteomics. Compared to conventional proteomics, the key difference in phosphoproteomics lies in the enrichment of phosphorylated peptides after enzymatic digestion, ensuring that mass spectrometry (MS) analysis selectively detects phosphorylated peptides (see Figure 1).

Various methods exist for phosphopeptide enrichment, with TiO₂ (titanium dioxide) being the most widely used material. TiO₂ selectively binds phosphate groups via electrostatic interactions in an acidic environment, enabling effective phosphopeptide enrichment. Another commonly used method is IMAC (immobilized metal affinity chromatography), which utilizes solid-phase metal ions (such as Fe³⁺ or Ga³⁺) that exhibit high affinity for phosphate groups. IMAC remains effective even in complex samples but may be affected by non-specific binding to acidic amino acid-containing peptides.

In addition, antibody-based phosphopeptide enrichment employs site-specific antibodies to study phosphorylation modifications on particular proteins or sequences. Antibody-based approaches help overcome the limitations of TiO₂ and IMAC in enriching low-abundance peptides or rare phosphorylation sites, such as tyrosine phosphorylation. To achieve higher enrichment efficiency and broader coverage, multiple phosphopeptide enrichment techniques can be combined based on specific experimental objectives.

 

Reproducibility of Phosphoproteomics

With continuous advancements in mass spectrometry (MS) technology and data acquisition methods, conventional proteomics has achieved high reproducibility across most sample types. However, phosphoproteomics exhibits relatively lower reproducibility due to several key factors:

  1. Dynamic nature of phosphorylation: Phosphorylation is a highly dynamic post-translational modification (PTM) that responds rapidly to cellular states, signaling pathway activation, and external stimuli.
  2. Stability of phosphorylation sites: During sample extraction, phosphate groups are susceptible to degradation by phosphatases, impacting the detection of phosphorylated peptides.
  3. Signal loss during enrichment: Phosphoproteomics requires enrichment of phosphorylated peptides before MS analysis, significantly reducing the number of peptides that ultimately enter mass spectrometry, thereby increasing technical variability compared to conventional proteomics.

Strategies to Improve Reproducibility

To address these challenges, phosphoproteomics demands higher standards for sample quality and experimental procedures:

Significance of Technical Replicates in Phosphoproteomics

Due to the inherent dynamic and unstable nature of phosphorylation, we strongly recommend including at least 2-3 technical replicates for each experimental condition. Technical replicates effectively reduce random errors during experiments, enhance the stability of phosphopeptide detection, and ensure a more comprehensive phosphorylation landscape.

In practical studies, increasing the number of technical replicates helps mitigate noise caused by individual variability and enhances statistical reliability, leading to more robust and credible experimental conclusions.

While the reproducibility of phosphoproteomics is inherently more challenging than conventional proteomics, optimizing sample handling, refining experimental workflows, and incorporating sufficient technical replicates can significantly minimize technical artifacts and improve data reliability and robustness.

 

Data interpretation

Spectral Library Searching

Spectral library searching is a critical step in mass spectrometry (MS)-based proteomics for interpreting experimental data. This process involves matching fragment ion spectra from Data-Independent Acquisition (DIA) experiments against spectral or sequence databases, enabling protein identification and quantification. Traditionally, spectral library searching has relied on reference libraries constructed from Data-Dependent Acquisition (DDA) experiments, where identified peptides from DDA data serve as the basis for matching. However, DDA-based libraries often suffer from limited coverage and batch-to-batch variability, which can compromise the sensitivity and reliability of peptide identification.

In recent years, in silico-predicted spectral libraries have emerged as a powerful alternative. Unlike traditional DDA-based approaches, these methods use computational tools such as deep learning models (e.g., Prosit) or physicochemical property-based algorithms (e.g., DeepMass) to predict peptide fragmentation patterns. This strategy significantly expands the coverage of searchable spectra while reducing reliance on experimental data. Additionally, some modern search engines now enable library-free DIA analysis, where high-confidence peptide identifications are extracted directly from DIA data, further enhancing analytical flexibility and robustness.

Among the most widely used tools for DIA data analysis, DIA-NN and Spectronaut provide advanced solutions for spectral library searching. DIA-NN is known for its computational efficiency, stringent false discovery rate (FDR) control, and robust library-free searching capabilities, making it particularly suitable for large-scale DIA data analysis. Its adaptive search strategies and built-in predicted libraries allow for comprehensive data interpretation without requiring additional DDA input. Spectronaut, on the other hand, excels in advanced scoring algorithms and sophisticated visualization tools, making it ideal for in-depth exploration of search results. Selecting the appropriate tool and optimizing the searching strategy are crucial for maximizing the accuracy and efficiency of DIA-based proteomics workflows.

When performing DIA-based spectral library searching, several key factors should be considered to ensure accuracy and reproducibility. FDR control is critical, as DIA-NN applies a global FDR strategy that requires careful threshold selection (typically 1%), while Spectronaut utilizes q-value-based filtering, which should be adjusted based on data quality. Additionally, sample quality and data preprocessing play a vital role in search performance—consistent sample preparation and minimizing technical noise are essential for obtaining reliable results. Computational resource optimization is another important consideration: DIA-NN benefits from multi-core CPUs with high clock speeds, while Spectronaut requires substantial computational power and optimized storage I/O for handling large datasets efficiently.

By carefully managing these factors, researchers can improve the reliability of spectral library searching and achieve more accurate protein identification in DIA-based proteomics studies.

生物信息学分析

许多常见的转录组学分析方法,也可用于蛋白质组学的分析。如差异表达分析,功能性分析等。共表达网络分析等。需要注意的是,数据分布。磷酸化差异表达分析可以基于肽段,也可以基于位点。基于位点则会选择最高的磷酸化定量值进行分析。

Future analysis

Targeted proteomics(考虑第二版加进来)

In addition to large-scale proteome identification, mass spectrometry-based proteomics can also be applied to targeted protein quantification. Compared to untargeted proteomics, targeted proteomics provides higher sensitivity and accuracy for quantifying low-abundance proteins while minimizing interference from complex sample backgrounds. This approach typically employs targeted mass spectrometry (Targeted MS) techniques such as SRM (Selected Reaction Monitoring), MRM (Multiple Reaction Monitoring), and PRM (Parallel Reaction Monitoring).

 

SRM and MRM utilize triple quadrupole mass spectrometers (QqQ) to detect a specific precursor ion and either a single (SRM) or multiple (MRM) predefined fragment ions, enabling highly specific and low-noise quantification. In contrast, PRM leverages high-resolution, high-accuracy mass spectrometry (such as Q-Orbitrap or Q-TOF) to simultaneously monitor multiple precursor ions and all their fragment ions, eliminating the need to predefine target fragment ions. This provides greater flexibility in data acquisition and improved quantification accuracy in complex sample matrices.

 

In compared with untargeted proteomics techniques, MS-based targeted proteomics enables both relative quantification across different samples and absolute quantification (AQUA). The AQUA approach requires the synthetic incorporation of stable isotope-labeled peptides as internal standards, which are spiked into samples to establish a calibration curve correlating peptide concentration with mass spectrometric signal intensity. By applying a targeted acquisition method, such as PRM, the ratio of synthetic to endogenous peptide ion intensities is measured, allowing for precise calculation of the endogenous peptide concentration in the sample. This methodology enables highly accurate absolute quantification of target proteins.